Murphy Centurion Configurable Controller CE-05171N User Manual

Page 34

Advertising
background image

CE-05171N page 34 of 44

6

6..3

3..1

19

9 D

Diig

giitta

all IIn

np

pu

utt S

Stta

attu

us

s

The user can see the state of each digital input in a table—

whether it is open or closed.

6

6..3

3..2

20

0 D

Diig

giitta

all O

Ou

uttp

pu

utt S

Stta

attu

us

s

For each of the devices configured as In Use, the user can

see the state of each output and has the ability to Force an

output for the purpose of testing. A force is associated with a

timeout so that it will be automatically cancelled when return-

ing to normal operation.

6

6..3

3..2

21

1 A

An

na

allo

og

g IIn

np

pu

utt S

Stta

attu

us

s

The user can view the raw counts of the analog inputs for

troubleshooting.

6

6..3

3..2

22

2 A

An

na

allo

og

g O

Ou

uttp

pu

utt S

Stta

attu

us

s

The user can see the state of each output, and if in Test

mode, has the ability to Force an output for the purpose of

testing. Analog outputs under the control of PID or other

Control Output settings cannot be forced. To force a PID

controlled output, place the PID in Manual mode and operate

the manual output value.

TM

C

C

C

Diagnostico-Digital Inputs Screen

___________________________________

DIGITAL INPUT STATUS

X=CLOSED O=OPEN

1 X 0 0 X X X 0 0 8

9 0 0 0 X X X X X 16

17 0 0 0 0 0 0 0 0 24

25 0 0 0 0 0 0 0 0 32

MORE MENUS

___________________________________

___________________________________

___________________________________

___________________________________

___________________________________

TM

C

C

C

Diagnostic-Digital Outputs State Screen

___________________________________

DIGITAL OUTPUT STATUS

DIGITAL OUTPUT 1

DO 1 FLT LAMP OFF

DIGITAL OUTPUT 2
DIGITAL OUTPUT 3
DIGITAL OUTPUT 4

▼▲ ENTER-EDIT

MORE MENUS

___________________________________

___________________________________

DIGITAL OUTPUT 5

TM

C

C

C

Diagnostic-Analog Inputs Screen

___________________________________

ANALOG INPUT STATUS

ANALOG INPUT 1

AI 1 SUCT PRS 00000

ANALOG INPUT 2
ANALOG INPUT 3
ANALOG INPUT 4

▼▲

MORE MENUS

___________________________________

___________________________________

ANALOG INPUT 5

TM

C

C

C

Diagnostic Analog-Outputs Status Screen

___________________________________

ANALOG OUTPUT STATUS

ANALOG OUTPUT 1

AI 1 ENG SPEED 030.00

ANALOG OUTPUT 2
ANALOG OUTPUT 3
ANALOG OUTPUT 4

▼▲ ENTER-EDIT

MORE MENUS

___________________________________

___________________________________

ANALOG OUTPUT 5

Advertising