CE-05171N page 42 of 44

8.0 Glossary

A

An

na

allo

og

g IIn

np

pu

utt

Terminals A18 to A29 are analog inputs on the C3-1 Centurion main I/O module. Accepts

voltage signals within the range of (0 to 5) VDC or (4 to 20) mA and are compared to con-

troller set points or events.

B

Bo

oo

ott llo

oa

ad

de

err

Means by which the Centurion controller communicates with C3-3 Display and MConfigPro

to receive and transfer new or updated configurations and firmware; and ensure data and

configuration synchronization.

C

Co

on

nttrro

olllle

err S

Se

ett p

po

oiin

ntts

s User defines normal operating range for the controller to optimize the equipment. Set

points can also define some other threshold, exception or event that may require action.

Multiple set points are often applied to a process and they may be manipulated as needed

to meet changing conditions.

D

De

ea

ad

d b

ba

an

nd

d

The user set range at which input may fluctuate without the controller taking any action.

The range may be fixed or variable.

D

Diig

giitta

all IIn

np

pu

utt

Terminals 30 to 61 are the digital input channels. User selects whether digital input is nor-

mally open (N/O), or normally closed (N/C). Users may also associate these inputs with

transition times for indicating no-flow conditions on divider blocks.

E

Ev

ve

en

ntt

Defines the action required by the controller in response to any number of parameters.

Event actions range from simple alarm message to emergency shutdown (ESD).

M

Ma

ag

gn

ne

ettiic

c P

Piic

ck

k U

Up

p

Terminals 64 to 65 are for magnetic pick up.

M

Ma

ax

xiim

mu

um

m

Maximum of engineering applied scale to the Offset and Span.

M

Miin

niim

mu

um

m

Minimum of engineering applied scale to the Offset and Span.

N

No

o--F

Fllo

ow

w

Designed to protect against compressor or engine failures, the controller monitors the cycle

time of lubrication system cycles and if that cycle time falls under a user assigned value, the

controller will activate a defined associated action.

O

Offffs

se

ett

User defined value to correct for known variance in the raw data.

P

Pa

an

ne

ell R

Re

ea

ad

dy

y

In States, the first logical step in start up.

P

Pe

errm

miis

ss

siiv

ve

e

A process condition, (Digital Input or Analog Set point), that must be met in order for the

engine to start.

S

Siig

gn

na

all

An electrical quantity of voltage or current that is used to represent or signify some other

physical quantity.

S

Sp

pa

an

n

The difference between the full scale output and the offset as raw data.

S

Stta

arrtt D

De

ella

ay

y

A time delay function to prevent premature start up.

S

Stta

atte

e

Predefined parameter of logical steps needed to successfully start and maintain an engine.

T

Te

errm

miin

na

all E

Em

mu

ulla

atto

orr

Allows a user to modify the firmware to allow upload or download of a record to either the C3-3

display or the controller. Always download a configuration after a firmware change.

T

Th

he

errm

mo

oc

co

ou

up

plle

e

A device for measuring temperature consisting of two dissimilar metals of high purity for an

accurate temperature/voltage relationship. User defines whether the calibration is J or K.

Terminals 1 to 17 are for thermocouple inputs.