Maxtor SLD240 User Manual

Page 73

Advertising
background image

72


12.2 Communication Protocol

IMPORTANT: This section is designed to allow users to control the DVR via the RS -232 and

RS-485 ports. The following information is intended to be used by qualified professionals.

Do not make any changes to your system’s settings unless instructed by a qualified

technician.

12.2.0 General Command Format

<Lead Code = 0x41>, < Dest ID >, < Src ID >, <Main category >, <Second category >, {<Number

of parameters>,<Parameter 1>, <Parameter 2> ..,} <End Code= 0x4f>

Lead Code = 0x41

Dest ID = 0x01

Src ID = 0x20

Main Category

= 0x01 Keys and Signals

= 0x02 Command

Second Category

= 0x01 Handshake

= 0x02 Request Time/Set Time

= 0x06 Request System State

End Code= 0x4f

The different command types and their corresponding parameters are as follows:

12.2.1 Keys and signals

PC Send: <0x41>, <0x01>, <0x20>, <0x01>, <Key Value>, <0x4f>

< The value of a specific front panel key >

KEY_PLAY

1

KEY_STOP

3

KEY_PAUSE

4

KEY_POWER

5

KEY_REC

6

KEY_SETUP

7

KEY_ENTER

8

KEY_SEARCH

10

KEY_DISPLAY

11

KEY_UP

13

KEY_DOWN

14

KEY_LEFT

15

KEY_RIGHT

16

KEY_MONITOR

36

Advertising