Electrical connections – Moyer Diebel 301HT M2 User Manual

Page 11

Advertising
background image

3

Warning:

Electrical and grounding connections must comply with all local electrical codes or in the

absence of local codes then connections must comply with the National Electrical Code.
Warning: When working on the dishwasher, disconnect the main electric service and tag it to

indicate work is being done on that circuit.
1. The electrician should compare the electrical specifications on the machine electrical data

plate (located in the control panel) to the electrical power supply before connecting the

machine to the incoming service at a fused disconnect switch.

IMPORTANT: The 208-240V/60Hz/1PH electrical supply service for this machine must be a

2-wire plus ground service. For optional 208-240V/60Hz/3PH the electrical supply service

must be a 3-wire plus ground service.

2. On the 208V-240V models, a knockout is provided at the rear of the junction box for

electrical service connections. A fused disconnect switch or circuit breaker (supplied by

user) is required to protect each power supply circuit.

Note:

Leave enough electrical cable behind the machine so that the dishwasher

can be pulled forward a minimum of two feet to be serviced.

Electrical Connections

Refer to the

MACHINE ELECTRICAL CONNECTION DATA PLATE

for the

dishwasher power requirements.

Installation