Installation, Wiring and General Specifications 2.

2-21

When the CPU in the FX/A Series PLC is directly connected, up to four GOT units can be
connected to one PLC (1-to-N connection).
As the connection type, select "CPU PORT (RS232C)" or "CPU PORT (RS422)" in "CON-
NECTION" on the PLC TYPE screen.

System configuration

Note:

While the GOT display is used, peripheral units of the GOT and peripheral units used to cre-
ate sequence programs cannot be used except when the following system configuration is
realized using the FX

2N

-422-BD in the FX

2N

Series. Cables to connect such peripheral

units should be disconnected while the GOT display is used.

RS-232C

communication

15 m (49.2ft)

1st unit

2nd unit

3rd unit

4th unit

RS-422 communication

Maximum extension

distance: 30 m (98.4 ft)

Side of GOT

FX/A Series

RS-422C

communication

30 m (98.4 ft)

RS-232C

communication

15 m (49.2 ft)