2 replacement of battery, Replacement of battery -3 – MITSUBISHI ELECTRIC F940GOT-SWD-E User Manual

Page 91

Advertising
background image

F940GOT-SWD-E/LWD-E

Maintenance 5.

5-3

5.2

Replacement of battery

When the battery voltage drops, the control devices for system information set by the screen cre-
ation software becomes ON. The control devices are interlocking with auxiliary relays in the PLC.
It is recommended to attach a lamp using the output of the PLC so that the ON/OFF status of the
7th bit can be monitored from the outside.
For the details of control devices, refer to the Operation Manual.

Example :When the FX-PCS-DU/WIN are used.

When the head No. of the control devices is set to M0.

M6: Battery voltage drop Becomes ON when the battery voltage drops.
This control device is used in a sequence program as follows.

Example :When the SW1D5C-GOTR-PACK are used.

When the system information of the write device is set D20.

D24 b3: Battery voltage drop Becomes ON when the battery voltage drops.
This control device is used in a sequence program as follows.

M6

Y

Indication outside PLC

Battery voltage drop

M8000

M23

Y

Indication outside PLC

Battery voltage drop

M0V

D24 K1M20

Advertising