EM316EDFA User Guide


P/N 1294008-001 Rev D2

8


4.1.1 Management Control from the Network

• Output power or gain control

• Power or gain control limits

• Input power and output power readings

• Output gain reading

• Case temperature reading

• Alarm status including case temperature, loss of input power, loss of output power

• Amplifier status reading

• Software

reset

• Output power mute



4.1.2 EM316EDFA Alarm Output Pins

• Case

temperature

• Loss of input
• Loss of output



4.1.3 Operating Parameters


Automatic Gain Control (AGC) maintains a constant gain for the module. The tables below show
the constant operating parameters of each EDFA module type.

Thresholds

EM316EDFA-BR

EM316EDFA-LPR

Module Function

Booster

In-line /

Preamplifier

Input Threshold

-8 dBm

-30 dBm

Input Shutdown

-10 dBm

-32 dBm

Output Threshold

-10 dBm

-10 dBm

Small Signal Gain

9 dBm

25 dBm

Output Power

0 to 18 dBm

0 to15.5 dBm


Recommended Operating Conditions

EM316EDFA-BR

EM316EDFA-LPR

Input signal dynamic range

-10 to +9 dBm

-20 to +5 dBm

Output optical power range

0 to 18 dBm

0 to +15.5 dBm

Optical bandwidth

1528 t o1563 nm

1528 t o1563 nm