4 chassis context, 1 “show – MRV Communications EM316EDFA-BR User Manual
Page 27
Fiber Driver
®
EM316EDFA User Guide
P/N 1294008-001 Rev D2
18
5.2.4 Chassis Context
Command examples in this section are applied in the chassis-level context. The box below
shows the command to navigate to the chassis context from the login context.
5.2.4.1 “show”
The following CLI excerpt shows a Fiber Driver chassis system with an EDFA amplifier
module and an EM316LNXNM-OT network management (NM) module. Notice that the EDFA
module is listed in both slots 1.3 and 1.4.
Use the command line “?” (help character, shown below) to display command line
parameters for the show command.
fiberdriver# configure terminal
fiberdriver(config)#
fiberdriver(config)# chassis 1
fiberdriver(chassis/1)#
fiberdriver(chassis/1)# show
Model: NC316BU-16
Name: NC316BU-1
Temp(C): 25
Temp Min(C): 5
Temp Limit(C): 55
PS1: DC Bad PS2: AC Good
Fan1: good Fan2: good
Fan3: good
Chassis Traps: on Slot Change Traps: on Module Specific Traps: on
Port Traps: on Link Traps: on Loopback Traps: on
LIN Traps: on Port Change Traps: on Port Diags Traps: on
Number Of Slots: 16
Hardware Revision: 1
Slot Model Name Serial Number
==== =============== ======================
============================
1.2 EM316LNXNM-OT EM316LNXNM-OT at 1.2 00:2
1.3 EM316EDFAv EM316EDFAv at 1.3 N/A
0:1a:02:48:28
1.4 EM316EDFA EM316EDFA at 1.4 N/A
1.5 EM316E1MUX4RM EM316E1MUX4RM at 1.5 12:34:56:78:90:15
1.7 EM316EFE1MUXRJv EM316EFE1MUXRJv at 1.7 00:20:1a:77:88:99
1.8 EM316EFE1MUXRJ EM316EFE1MUXRJ at 1.8 00:20:1a:77:88:99
fiberdriver(chassis/1)#