6. connecting to weld output terminals – Miller Electric Big Blue 251D User Manual

Page 20

Advertising
background image

OM-480 Page 16

ether1 12/96 − 153 382-A / Ref. 206 029

Y Stop engine.
Y Improper handling or expo-

sure to ether can harm your

health. Follow manufactur-

er’s safety instructions on

cylinder.

Y Do not use Ether Starting Aid

while engine is running.

Open side door(s).
1

Ether Cylinder

2

Nozzle

Remove cover and clean cylinder

nozzle.
3

Clamp

4

Fitting

5

Cap

6

Valve

Remove cap and clean fitting.

Install cylinder on fitting. Tighten

clamp.

.

After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.

Put cap on fitting when cylinder is

removed.

1

2

3

4

6

5

5-5. Installing Ether Cylinder (Optional Ether Starting Aid)

Ref. 800 162-A

Open left side door.
1

Bracket

Route cables through bracket.
2

Positive (+) Weld Output

Terminal

3

Negative (−) Weld Output Ter-

minal

For Stick welding Direct Current

Electrode Positive (DCEP), con-

nect work cable to (−) terminal and

electrode holder cable to (+)

terminal.
For Direct Current Electrode Nega-

tive (DCEN), reverse cable

connections.
If equipped with optional polarity

switch, connect electrode holder

cable to Electrode (−) terminal and

work cable to Work (+) terminal.
For FCAW welding, connect work

cable to (−) terminal and wire feeder

cable to (+) terminal.
Close door.

Tools Needed:

5-6. Connecting To Weld Output Terminals

3/4 in

1

2

3

Advertising