OM-480 Page 19

6-2. Description Of Front Panel Controls (See Section 6-1)

.

This unit has a max OCV control circuit
that resets the Amperage/Voltage Con-
trol to maximum when the arc breaks.
When an arc is struck, weld output control
returns to the front panel or remote con-
trol setting. The Amperage/voltage Con-
trol adjusts amperage only when welding
and does not adjust open-circuit voltage.

1

Ampere Range Switch

Use switch to select weld amperage range.

For most welding applications, use lowest

amperage range possible to prevent arc out-

ages.
Y Do not switch under load.
2

Amperage/Voltage Control

Control adjusts amperage within range

selected by Ampere Range switch. Weld out-

put would be 148 A DC with controls set as

shown (50% of 95 to 200 A).
3

DC Voltmeter (Optional)

4

DC Ammeter (Optional)

5

Remote A/V Switch And Receptacle

(See Section 6-3)

6

Magnetic Shutdown Switch (Optional)

Use switch during start-up to bypass optional

engine shutdown system. System stops en-

gine if oil pressure is too low or oil temperature

is too high.
7

Engine Control Switch

To Start: turn switch to Start while pressing

Shutdown switch. Release switches when

engine starts.

.

If the engine does not start, let engine
come to a complete stop before attempt-
ing restart.

In Run position, engine runs at weld/power

speed. In Run/Idle position (optional), engine

runs at idle speed at no load and weld/power

speed with load applied.
To Stop: turn switch to Off position.
8

Battery Charging Warning Light

Light goes on when battery is not charging.
9

Oil Pressure Warning Light

Light goes on if oil pressure is too low. If unit

has automatic shutdown option, light also

goes on if oil temperature is too high.
Y Stop engine and fix trouble if either

light goes on.

10 Ether Starting Aid Switch (Optional)
Push switch up and release while cranking

engine to release ether.
Y Do not use Ether if engine is running.
11 Engine Hour Meter
12 Oil Temperature Gauge/Switch

(Optional)

13 Oil Pressure Gauge/Switch (Optional)
14 Polarity Switch (Optional)
Place switch in Straight position for electrode

negative, or Reverse position for electrode

positive.
15 Manual Shutoff Lever
Use lever to stop engine if engine control

switch does not work.

6-3. Remote A/V Control

1

A/V Control Switch

Use switch to select front panel or

remote amperage control.
2

Remote A/V Receptacle RC3

Connect optional remote control to

RC3.

S-0774

1

Min (70 A DC)

Max (148 A DC)

Example: Combination Remote Amperage Control

In Example:

Range = 95 to 200 A

Percentage Of Range = 50%

Max = 148 A DC (50% of 95 to 200)

Adjust Optional Remote Control

Set Switch

Set Range

Set Percentage