SECTION 8 − MAINTENANCE AND TROUBLESHOOTING

8-1. Routine Maintenance

Recycle engine

fluids.

Y Stop engine before maintaining.

.

See Engine Manual and Maintenance Label for impor-
tant start-up, service, and storage information. Service
engine more often if used in severe conditions.

*

To be done by Factory Authorized Service Agent.

Every 8 h

Wipe Up

Spills.

Check Fluid

Levels. See

Section 5-4.

Drain Water

From Fuel

System. See

Section 8-4.

FUEL

WATER

Every 50 h

Clean Air Filter.

See Section 8-3.

Clean And

Tighten Weld

Terminals.

Every 100 h

Clean

Cooling

System.

Clean And

Tighten

Battery

Connections.

Check air

cleaner hoses

for cracks and

loose clamps.

Every 200 h

Every 250 h

Replace

Unreadable

Labels.

Check And

Clean Spark

Arrestor. See

Section 8-8.

Every 500 h

Change Oil. See

Section 8-4.

Change Oil

Filter. See

Section 8-4.

Repair Or

Replace

Cracked

Cables.

Every 1000 h

Blow Out Or

Vacuum Inside.

During Heavy

Service,

Clean Monthly.

OR

Change Fuel

Filters. See

Section 8-4.

Service Welding

Generator Brushes

And Slip Rings.

Service More Often

In Dirty Conditions.*

1/2 in.

(13 mm)

Check

Belt

Tension.

Drain Sludge

From Fuel

Tank. See

Section 8-4.

FUEL

SLUDGE

Check

Valve

Clearance.*

Every 3000 h

Clean/Set

Injectors.*

Advertising