8-3. Servicing Air Cleaner

aircleaner4 9/02− 802 495 / Ref. S-0698-B

Y Stop engine.
Y Do not run engine without air

cleaner or with dirty element. En-

gine damage caused by using a

damaged element is not covered

by the warranty.

.

The air cleaner primary element can
be cleaned but the dirt holding ca-
pacity of the filter is reduced with
each cleaning. The chance of dirt
reaching the clean side of the filter
while cleaning and the possibility of
filter damage makes cleaning a risk.
Consider the risk of unwarrantable
equipment damage when determin-
ing whether to clean or replace the
primary element.

If you decide to clean the primary
element, we strongly recommend
installing an optional safety element
to provide additional engine protec-
tion. Never clean a safety element.
Replace the safety element after
servicing the primary element three
times.

1

Air Cleaner

2

Service Indicator (Optional)

3

Window

4

Reset Button

Service air cleaner element if red band

appears in window. A green band means

air cleaner is okay. Press button to reset

indicator.
Clean or replace primary element if dirty

(see note above before cleaning). Re-

place primary element if damaged. Re-

place primary element yearly or after six

cleanings.
5

Housing

6

Safety Element (Optional)

7

Primary Element

8

Cover

9

Dust Ejector

To clean air filter:
Wipe off cover and housing. Remove

cover and dump out dust. Remove

element(s). Wipe dust from inside cover

and housing with damp cloth. Reinstall

safety element (if present). Reinstall

cover.
Y Do not clean housing with air

hose.

Clean primary element with compressed

air only.
Air pressure must not exceed 100 psi

(690 kPa). Use 1/8 in (3 mm) nozzle and

keep nozzle at least 2 in (51 mm) from

inside of element. Replace primary ele-

ment if it has holes or damaged gaskets.
Reinstall primary element and cover

(dust ejector down).

2

3

4

1

Blow

Inspect

9

8

7

5

6

Keep nozzle

2 in (51 mm)

from element.