Safety information – Multiquip MQ Power Whisperwatt 60HZ Generator DCA150USJ2 User Manual

Page 10

Advertising
background image

page 10 — DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11)

saFety inFOrMatiOn

eleCtriCal SaFetY

DANGER

„

DO NOT touch output terminals during

operation. Contact with output terminals

during operation can cause

electrocution,

electrical shock or burn.

„

The electrical voltage required to

operate the generator can cause severe

injury or even death through physical contact with live

circuits. Turn generator and all circuit breakers

OFF

before performing maintenance on the generator or

making contact with output terminals.

„

never insert any objects into the output

receptacles during operation. This is

extremely dangerous. The possibility exists

of

electrical shock, electrocution or

death.

„

Backfeed to a utility system can cause

electrocution and/or property damage.

never connect the generator to a

building’s electrical system without

a transfer switch or other approved

device. All installations should be

performed by a

licensed electrician in accordance with

all applicable laws and electrical codes. Failure to do so

could result in electrical shock or burn, causing

serious

injury or even death.

power Cord/Cable Safety

DANGER

„

never let power cords or cables lay in water.

„

never stand in water while AC power from the

generator is being transferred to a load.

„

never use damaged or worn cables or cords when

connecting equipment to generator. Inspect for cuts in

the insulation.

„

never grab or touch a live power

cord or cable with wet hands. The

possibility exists of

electrical shock,

electrocution or death.

„

Make sure power cables are securely connected to the

generator’s output receptacles. Incorrect connections

may cause electrical shock and damage to the

generator.

NOTICE

„

alWaYS make certain that proper power or extension

cord has been selected for the job. See Cable Selection

Chart in this manual.

Grounding Safety

DANGER

„

alWaYS make sure that electrical circuits are properly

grounded to a suitable earth ground (ground rod) per

the National Electrical Code (NEC) and local codes

before operating generator.

Severe injury or death by

electrocution can result from operating an ungrounded

generator.

„

never use gas piping as an electrical ground.

Advertising