Output terMinal panel cOnnectiOns

UvWo terminal oUtpUt voltageS

Various output voltages can be obtained using the UVWO

output terminal lugs. The voltages at the terminals are

dependent on the position of the

voltage Selector Switch

and the adjustment of the

voltage regulator Control

Knob.
Remember the voltage selector switch determines the

range of the output voltage. The voltage regulator (VR)

allows the user to increase or decrease the selected

voltage.

3Ø-240/139 UvWo terminal output voltages

1. Place the voltage selector switch in the 3Ø 240/139

position as shown in Figure 20.

Figure 20. Voltage Selector Switch

3Ø-240/139V Position

2. Connect the load wires to the UVWO terminals as

shown in Figure 21.

Figure 21. UVWO Terminal Lugs

3Ø-240/139V Connections

3. Turn the voltage regulator knob (Figure 21) clockwise

to increase voltage output, turn counterclockwise to

decrease voltage output. Use voltage regulator

adjustment knob whenever fine tuning of the output

voltage is required.

Figure 22. Voltage Regulator Knob

3Ø-208v/1Ø-120v UvWo terminal output voltages

1. Place the voltage selector switch in the 3Ø 240/139

position as shown in Figure 23.

Figure 23. Voltage Selector Switch

3Ø-240/139V Position

2. Connect the load wires to the UVWO terminals as

shown in Figure 24.

Figure 24. UVWO Terminal Lugs

3Ш-208/1Ш-120V Connections Connections

NOTICE

To achieve a 3Ø 208V output the voltage selector switch

must be in the 3Ø-240/139 position and the voltage

regulator must be adjusted to 208V..