Maintenance – Multiquip MQ Power Whisperwatt 60HZ Generator DCA150USJ2 User Manual

Page 53

Advertising
background image

DCa150USJ2 60 hz generator • operation anD partS manUal — rev. #0 (08/22/11) — page 53

*

1

Replace engine oil and filter at 100 hours, first time only.

*

2

Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.

*

3

Replace primary air filter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).

*

4

If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot,

with no sags or dips that could collect moisture and/or oil.

Table 14. inspection/maintenance

10 Hrs

DailY

250 Hrs 500 Hrs

1000

Hrs

Engine

Check Engine Fluid Levels

X

Check Air Cleaner

X

Check Battery Acid Level

X

Check Fan Belt Condition

X

Check for Leaks

X

Check for Loosening of Parts

X

Replace Engine Oil and Filter *

1

X

Clean Air Filter

X

Check Fuel Filter/Water Separator Bowl

X

Clean Unit, Inside and Outside

X

Change Fuel Filter

X

Clean Radiator and Check Coolant Protection Level*

2

X

Replace Air Filter Element *

3

X

Check all Hoses and Clamps *

4

X

Clean Inside of Fuel Tank

X

Generator

Measure Insulation Resistance Over 3M ohms

X

Check Rotor Rear Support Bearing

X

Maintenance

general inSpeCtion

Prior to each use, the generator should be cleaned and

inspected for deficiencies. Check for loose, missing or

damaged nuts, bolts or other fasteners. Also check for

fuel, oil, and coolant leaks. Use Table 14 as a general

maintenance guideline

Engine Side (Refer to the Engine

Instruction Manual)

air Cleaner

Every 250 hours: Remove air cleaner element (Figure 57)

and clean the heavy duty paper element with light spray of

compressed air. Replace the air cleaner as needed.

air Cleaner with Dust indicator

This indicator (Figure 57) is attached to the air cleaner.

When the air cleaner element is clogged, air intake

restriction becomes greater and the dust indicator signal

shows

RED meaning the element needs changing or

service. After changing the air element, press the dust

indicator button to reset the indicator.

Figure 57. Air Cleaner/Indicator

NOTICE

The air filter should not be changed until the indicator

reads

“RED”. Dispose of old air filter. It may not be

cleaned or reused.

Advertising
This manual is related to the following products: