Section 3 − introduction, 1. included with your unit, 2. specifications – Miller Electric Blu-Fab 3500 User Manual

Page 11: 3. duty cycle chart, 4. volt-ampere curves

Advertising
background image

OM-221 677 Page 7

SECTION 3 − INTRODUCTION

3-1. Included with Your Unit

1

Power Source

2

Power Cord (4m)

3

Work Cable and Clamp (4m)

4

Running Gear

1

2

4

3

3-2. Specifications

Rated Output

at 45% Duty

Cycle

Welding

Range

Max. OVC

Input Rating

KVA

Dimensions

Net Weight

Blu-Fab 3500

350 A 32 V

16-32

38

400−18A

11.8 KVA

Length: 1040mm

Height: 760mm

Width: 435mm

146 kg

Blu-Fab 4500

450 A 37 V

14-37

47

400-27A

17.7 KVA

Length: 1040mm

Height: 760mm

Width: 435mm

156 kg

3-3. Duty Cycle Chart

4.5 Minutes

Welding

5.5 Minutes

Resting

Duty cycle is percentage of 10

minutes that unit can weld at rated

load without overheating.
Y Exceeding duty cycle can

damage unit and void

warranty.

Blu-Fab 3500: 45% Duty Cycle at 32V, 350A
Blu-Fab 4500: 45% Duty Cycle at 37V, 450A

20 25 30

40 50 60 708090100

35

800
700
600
500

400

300

200

WELDING

AMPERES

% DUTY CYCLE

350

450

3-4. Volt-Ampere Curves

Blu-Fab 3500

Blu-Fab 4500

Advertising
This manual is related to the following products: