3. electrical service guide, 4. connecting input power, 5. remote 14 receptacle rc1 – Miller Electric Blu-Fab 3500 User Manual

Page 13

Advertising
background image

OM-221 677 Page 9

4-3. Electrical Service Guide

Blu-Fab 3500

Blu-Fab 4500

Input Voltage

400

400

Input amperes at rated output

21A

30A

Fuse or circuit breaker rating (max. rec)

21A

30A

Input conductor size

6 mm

2

6 mm

2

Grounding conductor size**

6 mm

2

6 mm

2

** Larger power cord may be required for cable length greater than 3 meters. Consult national or local regulations.

4-4. Connecting Input Power

Tools Needed:

Y Have only qualified persons

make this installation.

Y Special installation may be

required where gasoline or

volatile liquids are present −

consult national or local reg-

ulations.

GND/PE

Connect first.

GND/PE

L1

L2

L3

4-5. Remote 14 Receptacle RC1

Socket

Information

24 VOLTS AC

OUTPUT

A

24 volts ac.

24 VOLTS AC

OUTPUT

(CONTACTOR)

B

Contact closure to A completes 24 volts ac contactor control circuit.

OUTPUT

115 VOLTS AC

I

115 volts AC, protected by fuse.

OUTPUT

115 VOLTS AC

I

115 volts AC, protected by fuse.

GND

K

G

Chassis common.
Circuit common for 24 and 115 volts ac circuits.