2. panel controls, 3. run-in control and burnback control – Miller Electric Blu-Fab 3500 User Manual

Page 16

Advertising
background image

OM-221 677 Page 12

5-2. Panel Controls

1

2

3

4

5

7

8

9

10

6

1

Voltage Control

2

Purge Control

3

Jog

4

2T−4T Switch

5

Power ON-OFF

6

Torch Connection

7

Circuit Breaker

8

Gas In Connector

9

Control Cable Connection

10 Weld Cable Connection

5-3. Run-In Control and Burnback Control

2

4

6

8

10

2

4

6

8

10

t

Run-In Control
Use control to set wire feed speed

before arc initiation
After arc initiation, wire feed speed

is controlled by the wire feed speed

control on the front control panel.
Burnback Control
Control adjusts the time welding

wire is energized after wire feed

stops.