Section 6 − maintenance and troubleshooting, 1. routine maintenance, 2. troubleshooting – Miller Electric Blu-Fab 3500 User Manual

Page 17

Advertising
background image

OM-221 677 Page 13

SECTION 6 − MAINTENANCE AND TROUBLESHOOTING

6-1. Routine Maintenance

Y Disconnect power before maintaining.

.

Maintain more often during severe conditions.

3 Months

Replace unreadable labels.

Clean and tighten weld terminals.

Repair or replace cracked weld

cable.

Repair or replace cracked gas

hose.

Replace o-ring in Electrode/Gas

Output receptacle if cracked.

6 Months

Blow out or vacuum inside.

OR

6-2. Troubleshooting

Trouble

Remedy

No weld output; fan does not run.

Place line disconnect switch in On position (see Section 4-4).

Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 4-4).

Check for proper input power connections (see Section 4-4).

No weld output; fan on.

Check and replace if necessary.

Tighten wire feeder connection to Remote 14 receptacle.

Unit overheated. Allow unit to cool (see Section 3-3).

Fan not operating; weld output

available

Check for and remove anything blocking fan movement.

available.

Have Factory Authorized Service Agent check fan motor.