OM-223 839 Page 13

4-4. Trigger Mode Selection

.

Always check and set a trigger mode.
If trigger mode is undefined for a weld-

ing process, select the desired mode.

Trigger mode can be set for Manual MIG,

Synergic MIG, Synergic Pulsed MIG, and

Synegic Double Pulsed MIG welding to

change when output power is present at

the weld connectors. In Manual MIG, Syn-

ergic MIG, Synergic Pulsed MIG, and Syn-

ergic Double Pulsed MIG welding, press-

ing P1 will change trigger mode, but D1 and

D2 will not change values.
Press P1 to select the desired trigger

mode:
L10 ON selects 2 times trigger function.

When trigger is pressed, welding starts.
When trigger is released, welding stops.
L11 ON selects 4 times trigger function.
When trigger is pressed, welding starts.
When trigger is released, welding contin-

ues.
When trigger is pressed and released a

second time, welding stops.
L12 ON selects 3 levels trigger function.
When trigger is pressed, welding starts

with level 1 parameters.
When trigger is released, welding contin-

ues with main parameters.

When trigger is pressed a second time,

welding continues at level 2 parameters.
When trigger is released the second time,

welding stops.
L12 trigger mode is useful for aluminum

and for a crater fill sequence.
In Manual MIG process, 2 times and 4

times trigger mode can be selected.
In Synergic MIG process, 2 times, 4 times

and 3 levels can be selected.
In Synergic Pulsed MIG process, 2 times,

4 times, and 3 levels can be selected.
In Synergic Double Pulsed MIG process, 2

times, 4 times, and 3 levels can be se-

lected.

L10

L11

L12

P1

4-5. Setup Menu and Memory Menu Selection

L13 and L14 are generally OFF.
P2 selects the Setup Menu and the ad-

vance programming of MIG welding and to

memorize and manage personal welding

parameters in MIG welding.
Press P2 to select Setup Menu. L13 is ON.
Press P2 a second time to select Memory

Menu. L14 is ON.
Press P2 again to exit Setup and Memory

Menu. L13 and L14 are OFF.
In order to complete Setup and/or Memory

procedures you have to exit these menus.

L13 and L14 must be off.

.

In Setup Menu and Memory Menu you
cannot weld. This avoids setting er-

rors in the welding parameters and in

the memorized welding parameters.

L13

L14

P2