6. setup menu, 7. memory menu, 8. jog and purge selection – Miller Electric XMS 44 User Manual

Page 18

Advertising
background image

OM-223 839 Page 14

4-6. Setup Menu

Press P2 to enter SET UP menu.
Setup allows viewing and changing default

parameter values for all welding processes

for the desired weld characteristics.
D1 shows the welding parameter.
D2 shows the parameter value.
E1 changes the welding parameter.
E2 changes the parameter value.
P2 allows to exit setup Menu and Ad-

vanced Programming and to save the

changed parameters.

.

Incorrect settings in any process can
result in a program with undesirable

weld characteristics. Setup should

only be used by operators familiar with

various welding processes and pa-

rameters.

Setting Menu Type

To set menu type, proceed as follows:

Press P2 to enter Setup menu.

Use E1 to select SET (setup) SHO (short)

on D1 and D2 (default setting).
Use E2 to change D2 to FULL.

.

MENU SHORT only shows basic pa-
rameters for welding processes. SET-

UP FULL shows all parameters for

welding processes. Menu selection is

set when exiting the Setup Menu.

4-7. Memory Menu

Press P2 to enter Memory menu.

D1 shows the first free memory position or

the last memory used.

E1 changes the memory position number

from P.01 to P.99.

Any memory position contains all the se-

lected MIG welding parameters in the Wire

Feeder and in the Power Source.
When a memorized welding point is loaded

the Wire Feeder and the Power Source is

set accordingly.

Verify the Power Source status before

welding, if needed.

D1 shows the memory position.

E1 changes the memory position.

D2 shows the action you can perform on

the memory position.

E2 changes the action on the memory posi-

tion.

When D2 shows Ld (load), you can load in

the welder the parameters in the memory

position selected by D1.

When D2 shows Sto (storage), you can

memorize the actual welding parameters in

the memory position selected by D1.

When D2 shows dEL (delete), you can de-

lete the parameters memorized in the

memory position selected by D1.
In order to confirm the action, press P2 until

D1 and D2 flash.

Release P2 and wait until flashing stops.

The action is now performed and the weld-

er exits the Memory menu.

.

Do not perform any operation on the
welder when in Memory menu to pre-

vent incorrect weld parameters and

poor operation.

4-8. Jog And Purge Selection

.

If a function is selected and not used
within several seconds, the LED will

turn off .

To use the jog and purge function, proceed

as follows:
Pressing P3 once selects jog. Pressing P8

a second time selects purge.
When L15 illuminates, press and hold P3 to

perform jog function.

Jog feeds welding wire without weld output

power applied to the wire.
In Jog mode, D1 shows JOG and D2

shows wire feed speed.
Use E2 to change wire feed speed setting.

.

Jog will be performed if gun trigger is
pressed and held without striking a

welding arc. Front panel Jog is recom-

mended.

When L16 illuminates, press and hold P3 to

perform purge function.

.

Purge is used to remove impurities and
fill the gas hose with shielding gas.

Pre−Gas is a similar function, but only

operates at the beginning of a welding

process. Purge can be performed in

the TIG process by pressing the torch

trigger without striking an arc.

L15

L16

P3

Advertising