Multi-Tech Systems MTS2SA-T User Manual

Page 19

Advertising
background image

Chapter 4 – Command Line Interface (CLI)

Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)

19

General Commands – Setup

Command Syntax

set login

Description

Prompts the Login for the command shell when enabled, and doesn't when
disabled.

Default Value

Enable

Success

OK

Error

1. Too few arguments

"Usage: set login <enable/disable>

Type 'set login ?' for more information"
2. Invalid

string

"error: set login <enable/disable>"


Command Syntax

set login auto-dialout-login <enable/disable>

Description

Enables/Disables authentication for Telnet auto-dialout.

Default Value

Disable

Success

OK

Error

1. Too few arguments

"Usage: set login auto-dialout-login <enable/disable>

Type 'set login auto-dialout-login ?' for more information"
2. Invalid string
"error: set login auto-dialout-login <enable/disable>"


Command Syntax

set time <HH:MM:SS>

Description

Sets the system time.

Default Value

00:00:00

Success

OK

Error

1. Too few arguments

Usage: set date HH:MM:SS

Type 'set date ?' for more information

Error: Time in HH:MM:SS format

Too few arguments. Possible argument(s) are

ip login
serial date
ppp time


Command Syntax

set watchdog <enable/disable>

Description

Enables/Disables the watchdog timer.
The timer value is set to 6.5 seconds. This is the upper threshold value.

Note:

Watchdog timer comes into effect only after reboot. Hence,

invoking this command calls for a reboot on save.

Default Value

Enable

Success

OK

Error

1. Too few arguments

"Usage: set watchdog <enable/disable>

Type 'set watchdog <enable/disable> ?' for more information"
2. Invalid string
"error: set watchdog <enable/disable>"