Chapter 4 – Command Line Interface (CLI)

Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)

47

HTTP Server Commands – Setup

HTTP Server Commands

The commands in this section are listed in the order in which they might be used.

Command Syntax

set ip http-page <default/serial>

Description

This parameter is used by the http server to host the default HTML index or
host-defined http-serial-S0 HTML page.

Default Value

Default

Success

OK

Error

1. Too few arguments

“Usage: set ip http-page <default/serial>

Type set ip http-page ?”
2. Invalid string
Type "set ip http-page ?”


Command Syntax

set ip http <enable/disable>

Description

This enables the http server on the MultiConnect IP to listen on Port 80.

Default Value

Disable

Success

OK

Error

1. Too few arguments

“Usage: set "ip http <enable/disable>
Type 'set ip http ?' for more information"

2. Invalid string

"ERROR: Invalid string

Type 'set ip http ?' for more information"


Command Syntax

set ip http-port <port>

Description

Sets the HTTP server to listen on the specified port.

Default Value

80

Success

OK

Error

1. Too few arguments

“Usage: set ip http-port <port>
Type set 'ip http-port ?' for more information”

2. Invalid port number

"ERROR: Invalid port number

Type set 'ip http-port ?' for more information”


Command Syntax

set device-parameter P<n> <value>
where n = 0 to 99.

Description

Sets the value of the parameter from the host/serial device.

Default Value

Value in the default parameter list file uploaded through TFTP.

Success

OK

Error

1. Too few arguments

“Usage: set device P<n> <value>
Type 'set device P<n> ?' for more information”

2. Invalid string

"ERROR: Invalid string

Type 'set device P<n> ?' for more information”

Advertising