Metrologic Instruments Genesis MS7580 User Manual
Page 33

29
D
ESIGN
S
PECIFICATIONS
MS7580
D
ESIGN
S
PECIFICATIONS
E
LECTRICAL
+ 12 Volt
Adapter Value
+5 Volt
USB Power Value
Input Voltage:
12VDC ± 0.25V
5VDC ± 0.25V
Peak
3.1 W (Typical)
2.0 W (Typical)
Operating
2.3 W (Typical)
1.8 W (Typical)
Power:
Idle
1.7 W (Typical)
1.6 W (Typical)
Peak
260 mA (Typical)
408 mA (Typical)
Operation
192 mA (Typical)
362 mA (Typical)
Current:
Idle
142 mA (Typical)
322 mA (Typical)
Peak Values of at least 1 ms in width.
DC Transformer: Class 2; 12VDC @ 1.25 A
For regulatory compliance information see pages 37 - 39
E
NVIRONMENTAL
Operating = 0°C to 40° (32° to 104°F)
Temperature:
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 0% to 95% Relative Humidity, Non-Condensing
Light Levels: Up to 50,000 Lux
Shock: Designed to withstand 1.5 m (5’) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None
required
Specifications are subject to change without notice.