MQ SP-3035 CONCRETE SAW — OPERATION AND PARTS MANUAL — REV. #3 (09/29/06) — PAGE 39

MQ SP-3035 CONCRETE SAW

If an attempt is made to start the saw with the blade pinched, the starter will suffer damage. If an
attempt is made to use the lift pump to raise the saw to free the blade, the lift motor and front axle
could be damaged. If an attempt is made to lift the saw and blade out of the cut utilizing
equipment such as a loader or back hoe, the saw frame and axle are likely to be damaged.


CAUTION

If the Water System is not drained when the saw is not in use and

temperatures fall below 32˚F, damage may occur to optional water

pumps and/or oil coolers.

Draining the Water System

When low temperatures fall below 32˚F:
1. If the saw is equipped with an optional Water Pump, open the drain petcock on the pump and

allow the pump to drain.

2. With the engine running, turn the water pump switch on for a few seconds to purge water

remaining inside the pump body.

3. Tilt the saw up and back, to allow water to drain.
4. Tilt the saw forward, to allow water to drain again.

If an air compressor is available, blow out the system by applying compressed air to the Water
Inlet