Multi-Tech Systems MT2834ZPX User Manual

Page 28

Advertising
background image

28

MT2834ZPX Owner's Manual

COMMAND:

&En (Cont'd)
&E3 selects no modem-initiated flow control.
&E4 selects CTS modem-initiated flow control.
&E5 selects Xon/Xoff modem-initiated flow control.
&E6 selects Xon/Xoff not passed through.
&E7 selects Xon/Xoff passed through.
&E8 selects Enq/Ack pacing off.
&E9 selects Enq/Ack pacing on.
&E10 selects Normal Mode flow control off.
&E11 selects Normal Mode flow control on.
&E12 selects Pacing off.
&E13 means Pacing on.
&E14 means data compression disabled.
&E15 means data compression enabled.

COMMAND:

%En

VALUES:

n=0 thru 5

DEFAULT:

%E1

DESCRIPTION:

%E0 = Modem Won’t Escape.
%E1 = +++ Method (default setting).
%E2 = Break Method.
%E3 = Either +++ or Break Method.
%E4 = No "OK" Response to +++
%E5 = "OK" Response to +++

COMMAND:

#Fn

VALUES:

n = 0 thru 2

DEFAULT:

#F2

DESCRIPTION:

#F0 means no fallback when on-line.
#F1 means fallback from 33600 to 4800 bps

when on-line (increments of 2400 bps).

#F2 means fallback to 4800 bps from 33.6K

bps/fall forward if line improves (increments
of 2400 bps).

COMMAND:

&Fn

VALUES:

n = 0, 8 or 9

DEFAULT:

&F8

DESCRIPTION:

&F loads factory default values from ROM.
&F8 reads factory default values when &F is issued.
&F9 reads parameters stored in nonvolatile

memory when &F is issued.

Advertising