7. feeder set up push button, 8. adjust control – Miller Electric Axcess User Manual

Page 24

Advertising
background image

OM-211 076 Page 20

5-7. Feeder Set Up Push Button

1

Feeder Set Up Push Button

2

Feeder Set Up Push Button LED

Press button to choose sequence, trigger

control, or trigger hold.
3

Sequence LED

4

Trigger Control LED

5

Trigger Hold LED

6

Lock LED (Access Allowed Only By

Using An Optional PDA With File

Management Software)

When the Feeder Set Up button is pressed

while in standby, the Feeder Set Up push

button LED illuminates and the top display

will be active. Use the Adjust control to

select preflow (PRE), start (STRT), crater

(CRTR), or postflow (POST) parameters.

Press the lower display push button to allow

the bottom display to become active. The

time LED will automatically begin flashing

and the unit will be in the time mode. Initially,

all sequences will appear as off. Use the

Adjust control display time and enable the

time sequence. Setting a time automatically

enables a sequence. To turn off a sequence,

change time setting to OFF.

If the sequence has a voltage or arc adjust

setting, pressing the lower display push

button a second time will cause either volts

or arc adjust to appear on the display. Use

the Adjust control to set either parameter.

If the sequence has a wire feed setting,

pressing the lower display push button a

third time will cause wfs to appear on the

display. Use the Adjust control to set wire

speed parameter.

Press the lower display push button a fourth

time will cycle the display back to time.

Press the Feeder Set Up button a second

time to go to Trigger Control mode and allow

the top display to become active. Use the

Adjust control to cycle through trigger

control methods as follows: dual schedule,

trigger hold, trigger dual schedule, program

select, 4T (see Section 5-1). The lower

display will show the current state of each

trigger control method as being either on or

off. Not all trigger control methods are

compatible with each other, and turning on

certain functions will cause other trigger

functions to turn off.

Press the lower display push button to allow

the bottom display to become active. Use

the Adjust control to turn selected trigger

control methods on or off. If trigger hold is

set to on, the trigger hold LED will illuminate.

Note: if 4T is set to on, trigger hold will

automatically be set to on since this

parameter is necessary for the 4T function.

Press the Feeder Set Up button a third time

to cycle back to standby mode.

1

6

3

4

Trigger Control

Feeder Set Up

Trigger Hold

Sequence

5

Welding Sequence Diagram

Preflow

Time

Start

Time

Weld

Time

Crater

Time

Postflow

Time

2

5-8. Adjust Control

Adjust

1

1

Adjust Control

The Adjust control is used to

change various sequence parame-

ters, and to select various se-

quences. Refer to the section for

the function in question for informa-

tion related to using the Adjust con-

trol.

Advertising