OM-211 076 Page 24
SECTION 6 − SETTING SEQUENCE PARAMETERS
6-1. Sequence Parameters In A Program
.
For more information on
Sequence mode, see Feeder
Set Up Push Button in Section
If time is set to Off in Weld
sequence, welding continues until
gun trigger is released.
If time is set to zero in any timed
sequence except Weld, the
sequence is skipped.
.
Maximum IPM may actually
be lower depending on wire
size and gas combination.
Trigger
Pressed
Trigger
Released
Time
Start
Time
Preflow
Weld
Crater
Time
Postflow
Start
Time
Time
Postflow
Crater
Weld
Preflow
Sequence
End
Volts/Trim
IPM
Seconds
2. Postflow
Off-5.0
X = Setting available.
1. Preflow
Off-5.0
Sequence
Parameters
3. Start
4. Crater
Off-5.0
Off-5.0
10.0-44.0/
0-99
40-1400/
0-99
10.0-44.0/
0-99
40-1400/
0-99
Advertising