5-10. Jog/Purge

Pressing the Jog/Purge switch allows the

operator to jog wire without energizing the

weld power or gas valve circuit.

The unit provides the ability to jog the wire

feeder by means of the gun trigger or the

Jog/Purge switch. If the welding arc does

not initiate in 3 seconds after the gun trigger

is activated, the unit will perform a jog

operation for a maximum of 30 seconds. If

the gun trigger is still activated after 30

seconds, the jog operation is terminated to

prevent complete unspooling of the wire, in

the case of a damaged gun. The unit

displays the “ERR STRT“ message to

inform the operator that the trigger is

activated.

Jog speed can be adjusted by the Adjust

control when the unit is jogging wire. The

unit displays jog speed when the unit is

being jogged.

Jogging can also be accomplished by

pressing the Jog/Purge button.

Pressing the Jog/Purge button also allows

the operator to purge gas lines before

welding and to preset gas pressure at the

regulator.

This unit is equipped with Auto Thread

capability. By rocking the switch from purge

to jog within 0.5 seconds will automatically

feed wire for a factory default setting of 192

in (4877 mm) of wire before stopping. The

default feed rate is 700 ipm. These settings

can be changed using an optional PDA with

File Management software. Pressing the

Jog/Purge switch or gun trigger during Auto

Threading will terminate the automatic feed

operation.

1

803 505-A

2

3

1

Jog/Purge Push Button

2

Adjust Control

3

Gun Trigger Receptacle