Weld motr com pls wait, Over crnt low wfs, Estop – Miller Electric Axcess User Manual

Page 31: Rmd done over aver, Rel trig err unkn, Wait, 2 . diagnostics (continued)

Advertising
background image

OM-211 076 Page 27

7-2.

Diagnostics (Continued)

WELD WAIT

The weld wait error indicates unit was not

ready for a weld sequence. Press Jog/

Purge button to clear error.

MOTR COM

The motor communication error indi-

cates motor board lost data communica-

tions. Press Jog/Purge button to clear error.

PLS WAIT

The uim communication error indicates

user interface board lost data

communications. Press Jog/Purge button

to clear error.

OVER CRNT

The over current error indicates welding

power source primary current is too high.

Check and correct input power. Press Jog/

Purge button to clear error.

LOW WFS

The low wire feed speed error indicates

actual wire feed speed is lower than wire

feed speed command. Check for

obstructions in the wire feed system or a

faulty wire drive system. Press Jog/Purge

button to clear error.

E STOP

The emergency stop error occurs if the

user presses an emergency stop button.

Reset the emergency stop button and press

Jog/Purge button to clear error.

RMD DONE

The RMD done error indicates the RMD

demo is completed. Press Jog/Purge button

to clear error.

OVER AVER

The over average error indicates that cur-

rent is outside the average range for the set

program parameters. Check and correct

program parameters. Press Jog/Purge but-

ton to clear error.

REL TRIG

The release trigger error indicates the

user held the trigger when starting a weld

program Press Jog/Purge button to clear

error.

ERR UNKN

The unknown error indicates a malfunc-

tion in the system somewhere. Press Jog/

Purge button to clear error.

WELD

MOTR

COM

PLS

WAIT

Indicates a weld

cycle wait error.

Indicates a motor

communication error.

Indicates a UIM

communication error.

OVER

CRNT

LOW

WFS

Indicates an

overcurrent error.

Indicates a low WFS

command error.

E

STOP

Indicates an

emergency stop error.

RMD

DONE

OVER

AVER

Indicates an arc

error.

Indicates an over

average current error.

REL

TRIG

ERR

UNKN

Indicates a trigger

closed error.

Indicates an

unknown error.

WAIT