2. diagnostics, Err tach motr err wfs, Err strt err stop – Miller Electric Axcess User Manual

Page 30: Err flow err cool err gnd err stuk, Err temp err line err arc

Advertising
background image

OM-211 076 Page 26

7-2. Diagnostics

ERR TACH

The tach error occurs 2 seconds after the

loss of tachometer feedback. The motor

speed is regulated through the monitoring of

voltage and current. Press Jog/Purge

button to clear error.

ERR MOTR

The motor error indicates that the motor

has been drawing too much current for too

long. To remedy this, reduce the wire feed

speed or the wire feeder torque load/duty

cycle. Press Jog/Purge button to clear error.

ERR WFS

The wire feed speed error indicates actual

wire feed speed does not match wire feed

speed command. Press Jog/Purge button

to clear error.

ERR STRT

The start error occurs if the user has the

trigger held for more than 3 seconds without

striking an arc, or if a valid arc voltage and

current is not detected. The 3 second arc

start error time can be changed using an op-

tional PDA with File Management software.

ERR STOP

The stop error occurs as result of

obstructions in the wire feed system or a

faulty wire drive system. Check wire feed

and wire drive systems. Press Jog/Purge

button to clear error.

ERR FLOW

The flow error indicates no gas flow to the

gun. The error may be reset by

reestablishing gas flow to the gun, and then

pressing the Jog/Purge button.

ERR COOL

The cool error indicates no coolant flow in

water flow switch option. The error may be

reset by reestablishing coolant flow to the

gun, and then pressing the Jog/Purge

button.

ERR GND

The ground current error occurs if weld

current is detected in the earth ground

connection. May be caused by a conductor

making contact with unit chassis. Check

and repair feeder weld connections. Press

Jog/Purge button to clear error.

ERR STUK

The stuck error occurs if the welding wire

sticks to the workpiece at the end of a weld.

May be caused by poor weld conditions.

The error may be cleared by cutting wire

from workpiece, and pressing the Jog/

Purge button.

ERR TEMP

The temperature error indicates welding

power source has overheated and

shutdown. The error may be cleared by

allowing unit to cool down, and pressing the

Jog/Purge button.

ERR LINE

The line error indicates input power is

outside of unit operating range. Check and

correct input power. Press Jog/Purge

button to clear error.

ERR ARC

The arc error indicates an arc outage

occurred possibly from a wire feeder error

or power source error. Check wire feeder

and power source. Press Jog/Purge button

to clear error.

ERR

TACH

MOTR

ERR

WFS

The following error messages are shown on the

upper and lower displays to indicate specific errors.

Explanations are in the text below:

ERR

STRT

ERR

STOP

Indicates a

tachometer error.

Indicates a motor

error.

Indicates a wire

feed speed error.

Indicates an arc

start error.

Indicates an arc

stop error.

ERR

FLOW

ERR

COOL

ERR

GND

ERR

STUK

Indicates a gas

flow error.

Indicates a coolant

flow error.

Indicates a ground

current error.

Indicates a wire

stuck error.

ERR

TEMP

ERR

LINE

ERR

ARC

Indicates a

temperature error.

Indicates a line

error.

Indicates an arc

error.