OM-1581 Page 14

4-7. Water-Cooled Gun Connections

1

Gas Hose

Connect to Gas fitting on feeder.
2

Water Hose

Connect to water to gun fitting on

feeder (left-hand threads).
3

Wire Conduit

4

Thumbscrew

5

Wire Conduit Block

Loosen thumbscrew, and insert

conduit through Wire opening until

it bottoms against block. Trim liner

if necessary, as close to the rolls

as possible. Tighten thumbscrew.
6

Gun Control Cable

Insert plug into gun control recep-

tacle, and tighten threaded collar.
7

Strain Relief

Remove strain relief as shown.
8

Power/Water Cable

9

Strain Relief

.

For guns that have wire con-
duits with replaceable liners,

the strain relief will need to be

removed from the control box.

Route cable through strain relief

and connect to weld/water from gun

outlet on feeder. Reinstall strain re-

lief. Close and latch door.

Ref. 802 536-E / Ref. 151 778-B / 152 456-A

1

2

3

6

8

7

4

3

5

5/8, 1-1/8 in

Tools Needed:

Left Side

9

Advertising
This manual is related to the following products: