OM-1581 Page 25

5-4. Run-In Speed Control

1

Run-In Speed Control

Use control to set wire feed speed

before arc initiation.
After arc initiation, wire feed speed

is controlled by the Wire Speed

Control on the welding gun (see

Section 5-12).
The scale around the control is per-

cent of full range, not wire speed.

As a general rule, set run-in speed

lower than welding wire feed speed.
Set control at 0 (zero) for scratch

start.

Ref. 176 700-A

1

5-5. Jog Switch

1

Jog Switch

Use switch to energize drive mo-

tors in feeder and gun without ener-

gizing welding power source con-

tactor. When switch is held up in

Jog position, wire speed is set by

Wire Speed Control on gun.

1

5-6. Voltage/Wire Speed Switch And Meter (Optional)

1

Voltage/Wire Speed Meter

2

Voltage/Wire Speed Switch

When switch is in Voltage position,

and operator is welding, meter dis-

plays arc voltage. Cable resistance

and poor connections may cause

displayed voltage to vary slightly

from actual voltage at welding arc.
When switch is in Wire Speed posi-

tion and operator is welding, meter

displays preset wire speed in in-

ches per minute. This wire speed is

set by Wire Speed Control on the

gun.
During run-in portion of weld cycle,

meter displays run-in speed as se-

lected on Run-In Speed control on

feeder (see Section 5-4).
When welding Direct Current Elec-

trode Negative (DCEN), meter

does not display accurate output

voltages; however, meter displays

accurate wire speed values.

1

2

Volt sensing lead must be con-

nected to workpiece for me-

ters to operate.