OM-1581 Page 26

5-7. Spot Controls (Optional)

1

Spot/Continuous Switch

Use switch to select either an un-

timed continuous weld cycle or a

timed spot weld cycle. Both weld

cycles consist of the following

steps: run-in, weld (untimed or spot

time), and burnback.
2

Time Range Switch

Use switch to select spot weld time

range.
3

Spot Time Control

Use control to set spot weld time.

Welding wire feeds at speed se-

lected on the gun Wire Speed Con-

trol. Spot time starts at arc initiation.
The scale around the control is

marked in seconds.
4

Burnback Time Control

Use control to adjust time (up to 0.25

seconds) that the welding wire is

electrically energized after the wire

stops feeding.
If welding wire sticks in the weld

puddle, increase burnback time. If

wire burns back into the gun contact

tip, decrease burnback time.
The scale around the control is

marked in fractions of a second.

1

2

3

4

5-8. Remote Voltage Control (Optional)

1

Voltage Control

Use control to adjust arc voltage at

the wire feeder.
The scale around the control is

marked in percent.

1

5-9. Power Switch

1

Power Switch

Use switch to turn unit On and Off.