10. voltage sensing lead connections – Miller Electric XR A User Manual

Page 21

Advertising
background image

OM-1581 Page 17

4-10. Voltage Sensing Lead Connections

Unit is factory set for constant volt-

age (CV) welding. To set unit for

constant current (CC) welding,

proceed as follows:
1

Terminal Strip 2T

2

Strain Relief

Loosen screws of strain relief.
3

Voltage Sensing Lead

Route ring terminal end of lead

through strain relief, and connect

ring terminal to terminal A of

terminal strip 2T. Tighten screws on

strain relief.
4

Motor Speed Control Board

PC1

5

Jumper Plug

6

Receptacle RC5

For constant voltage (CV) welding,

place jumper plug in INT. position.

Do not connect voltage sensing

lead clamp to workpiece.
For constant current (CC) welding,

place plug in EXT. position.

Connect clamp end of voltage

sensing lead to workpiece.
Reinstall right side panel.

Ref. 151 772-B

Tools Needed:

1/4 in

E D C B A

3

4

EXT

INT

RC5

3 2 1

6

5

1

3

2

Advertising