OM-808 Page 21

5-2.

Overload Protection

Ref. ST-124 643-A / Ref. ST-161 156-A

Fuse link F1, or fuse links F1 and F2
for dual models, protect the grid
from overload damage. If weld
output stops, check link(s) as
follows:

Turn Off welding power source and
disconnect input power.

1

Fuse Link (See Parts List For
Rating)

Check and replace fuse link(s), if
necessary.

Close rear access door.

Grid Rear Panel

Multi-Grid Rack

1

5-3.

Troubleshooting

Trouble

Remedy

No weld output.

Check and replace open fuse link(s), if necessary (see Section 5-2).

Check electrical input and output connections (see Section 3-3).

Erratic or improper weld output.

Select correct size weld cables according to Section 3-7.

Clean and tighten weld cable connections (see Section 3-3).

For dual models, be sure paralleling switch is in proper position (see Section 4-7).

If using remote control, be sure Fine Amperage control and 2-1/2 Ampere switch on grid are in the Off
position (see Section 4-5).