OM-4407 Page 24

6-2. Process/Contactor Switch On CC/CV Models

1

Process/Contactor Switch

Y Weld output terminals are ener-

gized when Process/Contactor

switch is in an Electrode Hot posi-

tion and the engine is running.

.

The unit will not return to idle speed
when Process/Contactor switch is in
a Wire or TIG mode and the remote
contactor is on (closure between
pins A and B on remote receptacle).

Use switch to select weld process and

weld output on/off control (see table be-

low and Section 5-9).
Place switch in Remote positions to turn

weld output on and off with a device con-

nected to the remote receptacle.
Place switch in Electrode Hot positions

for weld output to be on whenever the en-

gine is running.
Use Stick positions for air carbon arc

(CAC-A) cutting and gouging.
When switch is in a Stick position, the dig

circuit provides additional amperage

during low voltage (short arc length con-

ditions) to prevent “sticking” electrodes.
The dig circuit is disabled when switch is

in Wire or TIG positions.

1

802 850

Process/Contactor Switch Settings

Switch Setting

Process

Output On/Off Control

Switch Setting

Process

Output On/Off Control

Remote − TIG

GTAW With HF Unit, Pulsing Device, Or

Remote Control

At Remote Receptacle

Remote − Stick

Stick (SMAW) With Remote On/Off

At Remote Receptacle

Remote − Wire

MIG (GMAW)

At Remote Receptacle

Electrode Hot − Wire

MIG (GMAW)

Electrode Hot

Electrode Hot − Stick

Stick (SMAW),

Air Carbon Arc (CAC-A) Cutting And Gouging

Electrode Hot

Electrode Hot − Scratch

Start TIG

Scratch Start TIG (GTAW)

Electrode Hot

Advertising