7. overload protection (kohler-powered units) – Miller Electric Trailblazer DC User Manual

Page 45

Advertising
background image

OM-4407 Page 41

Y Stop engine.

.

When a circuit breaker or fuse
opens, it usually indicates a
more serious problem exists.
Contact a Factory Authorized
Service Agent.

1

Circuit Breaker CB5

CB5 protects the 24 volt ac output

to Remote receptacle RC4. If CB5

opens, 24 volt ac output to RC4

stops.
Press button to reset breaker.
2

Fuse F2 (See Parts List)

3

Fuse F6 (See Parts List)

F2 is located behind the front panel.

F2 protects the 115 volt output to

Remote Receptacle RC4. If F2

opens, 115 volt ac output to RC4

stops.
F6 protects the engine wiring sys-

tem from overload. If F6 opens,

engine will not crank.
4

Fuse F1 (See Parts List)

Remove side panel.
F1 protects the exciter excitation

winding from overload. If F1 opens,

weld and generator power output

stops.
Replace any open fuses. Reinstall

cover before operating unit.

3/8 in

802 851-A / Ref. 206 422

4

Tools Needed:

1

3

9-7. Overload Protection (Kohler-Powered Units)

2

Located behind front panel.

Advertising