2 radio test mode, 1 access the test mode, Radio test mode -2 4.2.1 – Motorola SSETM 5000 User Manual

Page 64: Access the test mode -2, Table 4-1, Initial equipment control settings -2, Section 4.2: “radio test, D in

Advertising
background image

November 11, 2004

6881094C12-A

4-2

Performance Checks: Radio Test Mode

4.2

Radio Test Mode

This section provides instructions for performing tests in display radio test mode.

4.2.1

Access the Test Mode

To enter the display radio test mode:

1. Turn the radio on.
2. Within 10 seconds of turning the radio on, press the one-dot side button five times in

succession.

The radio shows a series of displays that give information regarding various version numbers
and subscriber specific information. The displays are described in

Table 4-2

.

NOTE: When you turn the radio on normally, the radio performs a limited self-test. To allow the radio

to perform a full self-test, press and hold the top side button while turning the radio on. If the
self-test is successful, you hear a chirp. If the self-test is unsuccessful, you hear a single, low-
frequency tone and see an error code on the radio’s display. See

Table 8-2 on page 8-2

for

the power-up error codes.

Table 4-1. Initial Equipment Control Settings

System Analyzer

Test Set

Power Supply

Monitor Mode: Standard

Spkr/Load: Speaker

Voltage: 7.5 Vdc

Receiver Checks
RF Control: GEN
Output Level: -47 dBm
Modulation: 1 kHz tone
@3 kHz deviation
Frequency: Set to selected
radio RX frequency
Meter: AC Volts

Transmitter Checks
RF Control: MONITOR
Frequency: Set to selected
radio TX frequency
Meter: RF Display
Modulation Type: FM
Attenuation: 20 dB

PTT: OFF (center)

DC On/Standby: Standby

Meter Out: RX

Volt Range: 7.5 Vdc

Opt Sel: ON

Current: 2.5 Amps

Advertising