OM-2233 Page 20

B. Connecting Single-Phase Input Power

2/04 - Ref. 802 136-A

Y Installation must meet all National

and Local Codes − have only quali-

fied persons make this installation.

Y Disconnect and lockout/tagout in-

put power before connecting input

conductors from unit.

Y Always connect green or green/

yellow conductor to supply

grounding terminal first, and never

to a line terminal.

.

The Auto-Line circuitry in this unit au-

tomatically adapts the power source

to the primary voltage being applied.

Check input voltage available at site.

This unit can be connected to any in-

put power between 120 and 460 VAC

without removing cover to relink the

power source.

1

Black And White Input Conductor

(L1 And L2)

2

Red Input Conductor

3

Green Or Green/Yellow Grounding

Conductor

4

Insulation Sleeving

5

Electrical Tape

Insulate and isolate red conductor as

shown.
6

Input Power Cord.

7

Disconnect Device (switch shown in

the OFF position)

8

Disconnect Device Grounding

Terminal

9

Disconnect Device Line Terminals

Connect green or green/yellow grounding

conductor to disconnect device grounding

terminal first.
Connect input conductors L1 and L2 to

disconnect device line terminals.
10 Over-Current Protection
Select type and size of over-current

protection using Section 4-9 (fused dis-

connect switch shown).
Close and secure door on disconnect

device. Remove lockout/tagout device,

and place switch in the On position.

1

6

5

4

2

7

6

L1

L2

1

=GND/PE Earth Ground

3

3

1

8

9

10

Tools Needed: