Chapter 1. Technical description

25

Two hot-swap hard disk drive bays. An optional ServeRAID adapter can be
configured to form a RAID-1 disk array for the operating system.

The memory subsystem has a number of redundancy features, including
memory mirroring, as described in 1.7, “System memory” on page 19.

The layout of the front panel of the x440, showing the location of the drive bays,
power supplies and fans, is shown in Figure 1-13.

Figure 1-13 Front panel of the xSeries 440

1.10 Light Path Diagnostics

To limit the need to slide the server out of the rack to diagnose problems, a new
Light Path Diagnostics panel has been added to the front of the x440. This panel
can be ejected from the server to view all Light Path Diagnostics-monitored
server subsystems. In the event that maintenance is then required, the customer
can slide the server out from the rack and using the LEDs, find the failed or failing
component.

As illustrated in Figure 1-14 on page 26, Light Path Diagnostics is able to monitor
and report on the health of CPUs, main memory, hard disk drives, PCI-X and PCI
slots, fans, power supplies, VRMs, and the internal system temperature.

Power button

Reset button

Power-on light

Hot-swap fans

USB port

System-error light (amber)

Information light (amber)

SCSI activity light (green)

Locator light (blue)

CD-ROM drive

Hot swap
power supplies

Diskette drive

Light Path Diagnostics
panel (pulls out)

Hot swap
drive bays