z10 BC Performance

The performance design of the z/Architecture can enable

the server to support a new standard of performance for

applications through expanding upon a balanced system

approach. As CMOS technology has been enhanced to

support not only additional processing power, but also

more PUs, the entire server is modifi ed to support the

increase in processing power. The I/O subsystem supports

a greater amount of bandwidth than previous generations

through internal changes, providing for larger and faster

volume of data movement into and out of the server. Sup-

port of larger amounts of data within the server required

improved management of storage confi gurations, made

available through integration of the operating system and

hardware support of 64-bit addressing. The combined bal-

anced system design allows for increases in performance

across a broad spectrum of work.

Large System Performance Reference

IBM’s Large Systems Performance Reference (LSPR)

method is designed to provide comprehensive

z/Architecture processor capacity ratios for different con-

fi gurations of Central Processors (CPs) across a wide

variety of system control programs and workload envi-

ronments. For z10 BC, z/Architecture processor capacity

identifi er is defi ned with a (A0x-Z0x) notation, where x is

the number of installed CPs, from one to fi ve. There are

a total of 26 subcapacity levels, designated by the letters

A through Z.

In addition to the general information provided for z/OS

V1.9, the LSPR also contains performance relationships for

z/VM and Linux operating environments.

Based on using an LSPR mixed workload, the perfor-

mance of the z10 BC (2098) Z01 is expected to be:

• up to 1.4 times that of the z9 BC (2096) Z01.

Moving from a System z9 partition to an equivalently sized

System z10 BC partition, a z/VM workload will experience

an ITR ratio that is somewhat related to the workload’s

instruction mix, MP factor, and level of storage over com-

mitment. Workloads with higher levels of storage over

commitment or higher MP factors are likely to experience

lower than average z10 BC to z9 ITR scaling ratios. The

range of likely ITR ratios is wider than the range has been

for previous processor migrations.

The LSPR contains the Internal Throughput Rate Ratios

(ITRRs) for the z10 BC and the previous-generation

zSeries processor families based upon measurements

and projections using standard IBM benchmarks in a con-

trolled environment. The actual throughput that any user

may experience will vary depending upon considerations

such as the amount of multiprogramming in the user’s job

stream, the I/O confi guration, and the workload processed.

Therefore no assurance can be given that an individual

user will achieve throughput improvements equivalent

to the performance ratios stated. For more detailed per-

formance information, consult the Large Systems Perfor-

mance Reference (LSPR) available at:

http://www.ibm.com/servers/eserver/zseries/lspr/.

CPU Measurement Facility

The CPU Measurement Facility is a hardware facility which

consists of counters and samples. The facility provides a

means to collect run-time data for software performance

tuning. The detailed architecture information for this facility

can be found in the System z10 Library in Resource Link

.

17

Advertising