Parallel Sysplex Coupling Connectivity

The Coupling Facilities communicate with z/OS images in

the Parallel Sysplex environment over specialized high-

speed links. As processor performance increases, it is

important to also use faster links so that link performance

does not become constrained. The performance, avail-

ability and distance requirements of a Parallel Sysplex

environment are the key factors that will identify the appro-

priate connectivity option for a given confi guration.

When connecting between System z10, System z9 and

z990/z890 servers the links must be confi gured to operate

in Peer Mode. This allows for higher data transfer rates

to and from the Coupling Facilities. The peer link acts

simultaneously as both a CF Sender and CF Receiver link,

reducing the number of links required. Larger and more

data buffers and improved protocols may also improve

long distance performance.

Introducing long reach Infi niBand coupling links

Now, Infi niBand can be used for Parallel Sysplex coupling

and STP communication at unrepeated distances up to 10

km (6.2 miles) and even greater distances when attached

to a qualifi ed optical networking solution. Infi niBand cou-

pling links supporting extended distance are referred to as

1x (one pair of fi ber) IB-SDR or 1x IB-DDR.

• Long reach 1x Infi niBand coupling links support single

data rate (SDR) at 2.5 gigabits per second (Gbps) when

connected to a DWDM capable of SDR

• Long reach 1x Infi niBand coupling links support double

data rate (DDR) at 5 Gbps when connected to a DWDM

capable of DDR.

Depending on the capability of the attached DWDM, the

link data rate will automatically be set to either SDR or

DDR.

The IBM System z10 introduces Infi niBand coupling link

technology designed to provide a high-speed solution and

increased distance (150 meters) compared to ICB-4 (10

meters).

Infi niBand coupling links also provide the ability to defi ne

up to 16 CHPIDs on a single PSIFB port, allowing physi-

cal coupling links to be shared by multiple sysplexes.

This also provides additional subchannels for Coupling

Facility communication, improving scalability, and reduc-

ing contention in heavily utilized system confi gurations. It

also allows for one CHPID to be directed to one CF, and

another CHPID directed to another CF on the same target

server, using the same port.

Like other coupling links, external Infi niBand coupling

links are also valid to pass time synchronization signals for

Server Time Protocol (STP). Therefore the same coupling

links can be used to exchange timekeeping informa-

tion and Coupling Facility messages in a Parallel Sysplex

environment.

51

A robust failure recovery capability

ICF

z/OS

z/OS

ICF

System z10 / z9

zSeries 990 / 890

System z10 / z9

zSeries 990 / 890

z10 EC, z10 BC, z9 EC,

z9 BC, z990, z890

ICB-4 10 meters

12x PSIFB

12x PSIFB

HCA2-O

MBA

HCA2-C

I/O Drawer

ISC-3

ISC-3

ISC-3

ISC-3

z10 EC, z10 BC

IFB-MP

z10

ISC-3

New ICB-4 cable

z10 EC, z10 BC, z9 EC,

z9 BC, z990, z890

HCA2-O LR

Up to 150 meters

Up to 150 meters

Up to 10/100

Km

..

..

..

..

..

..

..

..

HCA2-O

..

..

..

..

..

..

..

..

1x PSIFB

Up to 10/100 Km

z9 EC and z9 BC S07