IBM Z10 BUISNESS CLASS Z10 BC User Manual

Page 30

Advertising
background image

OSA-Express Network Traffi c Analyzer is exclusive to the

z10 BC, z9 BC, z10 EC, and z9 EC, and is applicable

to the OSA-Express3 and OSA-Express2 features when

confi gured as CHPID type OSD (QDIO), and is supported

by z/OS.

Dynamic LAN idle for z/OS

Dynamic LAN idle is designed to reduce latency and

improve network performance by dynamically adjusting

the inbound blocking algorithm. When enabled, the z/OS

TCP/IP stack is designed to adjust the inbound blocking

algorithm to best match the application requirements.

For latency sensitive applications, the blocking algo-

rithm is modifi ed to be “latency sensitive.” For streaming

(throughput sensitive) applications, the blocking algorithm

is adjusted to maximize throughput. The z/OS TCP/IP stack

can dynamically detect the application requirements,

making the necessary adjustments to the blocking algo-

rithm. The monitoring of the application and the blocking

algorithm adjustments are made in real-time, dynamically

adjusting the application’s LAN performance.

System administrators can authorize the z/OS TCP/IP stack

to enable a dynamic setting, which was previously a static

setting. The z/OS TCP/IP stack is able to help determine

the best setting for the current running application, based

on system confi guration, inbound workload volume, CPU

utilization, and traffi c patterns.

Link aggregation for z/VM in Layer 2 mode

z/VM Virtual Switch-controlled (VSWITCH-controlled) link

aggregation (IEEE 802.3ad) allows you to dedicate an

OSA-Express2 (or OSA-Express3) port to the z/VM operat-

ing system when the port is participating in an aggregated

group when confi gured in Layer 2 mode. Link aggregation

(trunking) is designed to allow you to combine multiple

physical OSA-Express3 and OSA-Express2 ports (of the

same type for example 1GbE or 10GbE) into a single logi-

cal link for increased throughput and for nondisruptive

failover in the event that a port becomes unavailable.

• Aggregated link viewed as one logical trunk and con-

taining all of the Virtual LANs (VLANs) required by the

LAN segment

• Load balance communications across several links in a

trunk to prevent a single link from being overrun

• Link aggregation between a VSWITCH and the physical

network switch

• Point-to-point connections

• Up to eight OSA-Express3 or OSA-Express2 ports in one

aggregated link

• Ability to dynamically add/remove OSA ports for “on

demand” bandwidth

• Full-duplex mode (send and receive)

• Target links for aggregation must be of the same type

(for example, Gigabit Ethernet to Gigabit Ethernet)

The Open Systems Adapter/Support Facility (OSA/SF) will

provide status information on an OSA port – its “shared” or

“exclusive use” state. OSA/SF is an integrated component

of z/VM.

Link aggregation is exclusive to System z10 and System

z9, is applicable to the OSA-Express3 and OSA-Express2

features in Layer 2 mode when confi gured as CHPID type

OSD (QDIO), and is supported by z/VM 5.3 and later.

30

Advertising