Z10 bc confi guration detail – IBM Z10 BUISNESS CLASS Z10 BC User Manual

Page 62

Advertising
background image

Features

Min #

Max #

Max

Increments Purchase

Features Features Connections per

Feature Increments

16-port 0

(1)

32

480 channels 16 channels 4 channels

ESCON

1reserved as

as a spare

FICON

0

(1)

32

64/128*

2/4* 2/4*

Express4*

channels

channels channels

FICON

0

(1)

20

80 channels 4

channels 4 channels

Express2**

FICON

0

(1)

20

40 channels 2

channels 2 channels

Express**

ICB-4

0

(1)

6

12 links

(2) (3)

2

links

1 link

ISC-3

0

(1)

12

48 links

(2)

4

links

1 link

1x PSIFB

0

(1)

6

12 links

(2)

2

links

2 links

12x PSIFB

0

(1)

6

12 links

(2) (3)

2

links

2 links

OSA-

0

24

48/96*

2 or 4

2 ports/

Express3*

ports

4

ports

OSA-

0

24

24/48

1 or 2

2 ports/

Express2**

ports

1

port

Crypto

0

8

8/16 PCI-X

1/2* PCI-X 2* PCI-X

Express2*

adapters

adapters adapters

(4)

1) Minimum of one I/O feature (ESCON, FICON) or Coupling Link (PSIFB,

ICB-4, ISC-3) required.

2) The maximum number of external Coupling Links combined cannot

exceed 56 per server. There is a maximum of 64 coupling link CHPIDs
per server (ICs, ICB-4s, active ISC-3 links, and IFBs)

3) ICB-4 and 12x IB-DDR are not included in the maximum feature count for

I/O slots but are included in the CHPID count.

4) Initial order of Crypto Express2 is 2/4 PCI-X adapters (two features).

Each PCI-X adapter can be confi gured as a coprocessor or an accelera-
tor.

* FICON Express4-2C 4KM LX has two channels per feature, OSA-

Express3 GbE and 1000BASE-T have 2 and 4 port options and Crypto
Express2-1P has 1 coprocessor

** Available only when carried forward on an upgrade from z890 or or z9

BC. Limited availability for OSA-Express2 GbE features.

z10 BC Concurrent PU Conversions

• Must order (characterize one PU as) a CP, an ICF or an

IFL

• Concurrent model upgrade is supported

• Concurrent processor upgrade is supported if PUs are

available

– Add CP, IFL, unassigned IFL, ICF, zAAP, zIIP or

optional SAP

• PU Conversions

– Standard SAP cannot be converted to other PU types

To

CP IFL Unassigned ICF zAAP zIIP Optional

From

IFL

SAP

CP

X

Yes

Yes Yes Yes Yes Yes

IFL

Yes X

Yes Yes Yes Yes Yes

Unassigned

Yes Yes

X Yes Yes Yes Yes

IFL

ICF

Yes Yes

Yes X Yes Yes Yes

zAAP

Yes Yes

Yes Yes X Yes Yes

zIIP

Yes Yes

Yes Yes Yes X

Yes

Optional

Yes Yes

Yes Yes Yes Yes

X

SAP

Exceptions: Disruptive if ALL current PUs are converted to different types

may require individual LPAR disruption if dedicated PUs are converted.

62

z10 BC Confi guration Detail

Advertising