background image

32

• Cryptographic Cards: The PCIXCC and PCICA cards

plug in the I/O cage and can be added or replaced con-

currently with system operation.

• Redundant Cage Controllers: The Power and Service

Control Network features redundant Cage Controllers for

Logic and Power control. This design enables nondis-

ruptive service to the controllers and virtually eliminates

customer scheduled outage.

• Auto-Switchover for Service Element: The z990 has two

Service Elements. In the event of failure on the Primary

SE, the switchover to the backup is handled automati-

cally. There is no need for any intervention by the cus-

tomer or Service Representative.

Concurrent Capacity Backup Downgrade (CBU Undo)

This function allows the customer to downgrade the disas-

ter backup machine to its normal confi guration without

requiring the PowerOn Reset (POR).

Concurrent Memory Upgrade

This function allows adding memory concurrently, up to the

maximum amount physically installed.

Parallel Sysplex clustering was designed to bring the

power of parallel processing to business-critical zSeries

and S/390 applications. A Parallel Sysplex cluster consists

of up to 32 z/OS and/or OS/390 images coupled to one or

more Coupling Facilities (CFs or ICFs) using high-speed

specialized links for communication. The Coupling Facili-

ties, at the heart of the Parallel Sysplex cluster, enable

high speed, read/write data sharing and resource sharing

among all the z/OS and OS/390 images in a cluster. All

images are also connected to a Sysplex Timer

®

to address

time synchronization.

Parallel Sysplex Resource Sharing enables multiple system

resources to be managed as a single logical resource

shared among all of the images. Some examples of

resource sharing include Automatic Tape Switching (ATS

star), GRS “star,” and Enhanced Catalog Sharing; all of

which provide simplifi ed systems management, increased

performance and/or scalability. For more detail, please see

S/390 Value of Resource Sharing white paper – GF22-5115

on the Parallel Sysplex home page at ibm.com/servers/

eserver/zseries/pso.