z990 Frame and I/O Confi guration Content: Planning for I/O

The following diagrams show the capability and fl exibility

built into the I/O subsystem. All machines are shipped with

two frames, the A-Frame and the Z-Frame and can have

between one and three I/O cages. Each I/O cage has 28

I/O slots.

I/O Feature Type Features Maximum

ESCON 28 cards 420 channels

FICON Express 20 40 channels

OSA-Express 20 40 ports

PCIXCC 4 4

PCICA 2 4 cards

Maximum combined FICON Express, OSA-Express, PCICA/PCIXCC fea-
tures is 20.

I/O Feature Type Features Maximum

ESCON 35 cards 512 channels

FICON Express 40 80 channels

OSA-Express 24 48 ports

PCIXCC 4 4

PCICA 4 8 cards

Maximum combined FICON Express, OSA-Express, PCICA/PCIXCC fea-
tures is 40.

I/O Feature Type Features Maximum

ESCON 35 cards 0 channels

FICON Express 60 120 channels

OSA-Express 24 48 ports

PCIXCC 4 4

PCICA 6 12 cards

Maximum combined FICON Express, OSA-Express, PCICA/PCIXCC fea-
tures is 60.

General Information:

• ESCON confi gured in 4-port increments. Up to 28 chan-

nels in 2 cards, 60 channels in 4 cards, 88 channels in 6

cards.

• 120 in 8 cards, etc. up to a maximum 69 cards, 1024

channels.

• OSA-Express can be Gigabit Ethernet, 1000BASE-T

Ethernet or Token-Ring.

• Total number of PCIXCC / PCICA is 8 per system.

• If ICB-2 or ICB-3 are required on the system, these will

use up a single I/O slot for every 2 ICB-2 or ICB-3 to

accommodate the STI-2 and STI-3 cards.