IBM Enterprise Server H80 Series User Manual

Page 85

Advertising
background image

Updating System Firmware from the AIX Command Line

Refer to the detailed instructions that are provided on the Web site with the latest
image.

Note: The update process can take up to sixty minutes, and the system will always
reboot itself during the update process.

Recovery Mode

If the service processor detects that its programming has been corrupted when it is
powering up to standby mode, it will enter recovery mode. In recovery mode, it will
ask for the firmware update diskettes by putting eight-digit codes on the operator
panel.

The eight-digit codes are as follows:

Notes:

1. If the wrong diskette is inserted at any time, or if the diskette is left in the drive

after it has been read,

B1FD

1F

is displayed, indicating that the wrong diskette

is in the drive.

2. If

B1FD

1A

is displayed at any time during the process, the service processor

must be reset by removing and reconnecting ac power.

After the update process is complete, the service processor resets itself and goes
through a complete reboot.

Code

Action

A1FD 0000

System firmware has been corrupted and must be reflashed.

A1FD 0001

Insert update diskette 1.

A1FD 0002

Insert update diskette 2.

A1FD 0003

Insert update diskette 3.

Chapter 3. Using the Service Processor

69

Advertising