25

5

RECEIVE AND TRANSMIT

n

Filter setting

When an optional filter is installed, set the optional
filters in initial set mode. Optional filters are not
selected by default. (p. 47)

D Optional filter setting

q

While pushing and holding [SET], push [POWER]

to enter initial set mode.

w

Push [UP Y] or [Z DN] one or more times until

“FIL” appears on the display.

e

Rotate the tuning dial to select the installed filter.

• “no,” “52A,” “53A,” “96,” “222” and “257” indicate no

optional filter, FL-52A, FL-53A, FL-96, FL-222 and
FL-257, indicate respectively for 455 kHz IF filter
selection.

r

Push [PWR] to exit initial set mode.

D Expanded filter selection

The selectable filter combinations can be expanded
by setting the expanded filter selection to ON. Then
extra wide or narrow filter can be selected on desired
mode.

q

While pushing and holding [SET], push [PWR] to

enter initial set mode.

w

Push [UP Y] or [Z DN] one or more times until

“EXP FIL” appears.

e

Rotate the tuning dial to turn the expanded filter

selection ‘on’.

• If ‘on’ is selected, the expanded filter selection can be

used.

Wide/narrow filter selecting

r

Push [UP Y] one or more times

until “WIDE ” or “NAR ”
appears on the display.

t

Push [MODE] one or more times

to select the desired mode.

y

Rotate the tuning dial to select a

filter.

u

Repeat steps t and y to select

IF filters for other modes, if
desired.

• The filter combinations are stored

depending on operating modes.

i

Push [POWER] to exit initial set

mode.

no

FL-52A

FL-53A

FL-96

FL-222

FL-257

SSB

no

no

no

96 (2.8 K)

no

257(3.3 k)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

CW

no

no

no

96 (2.8 K)

no

257(3.3 k)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

RTTY

no

no

no

96 (2.8 K)

no

257(3.3 k)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

AM

– – –

– – –

– – –

– – –

– – –

– – –

no

FL-52A

FL-53A

FL-96

FL-222

FL-257

SSB

– – –

no

no

– – –

222 (1.8 K)

– – –

52A (500)

53A (250)

CW

– – –

52A (500)

53A (250)

– – –

222 (1.8 K)

– – –

RTTY

– – –

52A (500)

53A (250)

– – –

222 (1.8 K)

– – –

AM

NOR (2.4 K)

52A (500)

53A (250)

96 (2.8 K)

222 (1.8 K)

257 (3.3 K)

NOR (2.4 K)

NOR (2.4 K)

NOR (2.4 K)

NOR (2.4 K)

NOR (2.4 K)

: default

: default

no

FL-52A

FL-53A

FL-96

FL-222

FL-257

SSB

no

no

no

96 (2.8 K)

no

257(3.3 k)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

CW

no

no

no

96 (2.8 K)

no

257(3.3 k)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

RTTY

no

no

no

96 (2.8 K)

no

257(3.3 k)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

THU (6 K)

AM

– – –

– – –

– – –

– – –

– – –

– – –

no

FL-52A

FL-53A

FL-96

FL-222

FL-257

SSB

– – –

no

no

– – –

222 (1.8 K)

– – –

52A (500)

53A (250)

CW

– – –

52A (500)

53A (250)

– – –

222 (1.8 K)

– – –

RTTY

– – –

52A (500)

53A (250)

– – –

222 (1.8 K)

– – –

AM

NOR (2.4 K)

52A (500)

53A (250)

96 (2.8 K)

222 (1.8 K)

257 (3.3 K)

NOR (2.4 K)

NOR (2.4 K)

NOR (2.4 K)

NOR (2.4 K)

NOR (2.4 K)

: default

: default

Narrow filter setting table

Wide filter setting table

• Optional filter selection

• Expanded filter selection “on”

• Wide filter setting

• Narrow filter setting

Advertising