9

INSTALLATION AND CONNECTIONS

The UT-102 announces the received frequency, mode,
S-meter level and current time in a clear, electronically-
generated voice, in English (or Japanese).

Push [LOCK] for 1 sec. to announce the frequency,

etc.

q

Remove the bottom cover as shown above.

w

Remove the protective paper attached to the

bottom of the UT-102 to expose the adhesive strip.

e

Plug UT-102 into J2501 on the MAIN unit as

shown at right.

r

Return the bottom cover to its original position.

n

CR-338

high

stability

crystal

unit

By installing the CR-338, the total frequency stability
of the receiver will be improved.

q

Remove the bottom cover as shown in the

diagram before.

w

Disconnect W2 from J4401 (MAIN unit) and W3

from J4201 (MAIN unit).

e

Remove 9 screws from the PLL unit, disconnect

P4 from J201 (MAIN unit) and P2 from J401
(MAIN unit), then remove the PLL unit.

r

Remove the supplied internal crystal and replace

with the CR-338.

t

Return the PLL unit, plugs and flat cables to their

original positions.

y

Adjust the reference frequency at C16 using a

frequency counter if desired.

• Connect the frequency counter to P. 2 (PLL unit).

u

Return the bottom cover to its original position.

CR-338

Internal crystal

PLL unit

W 3

W 2

J 4201

J 4401

P 4

J 201

J 401

P 2; Frequency check point
(Connect a frequency counter
and adjust the frequency to
64.00000 MHz with C 16.)

C 16